Pump Assembly

Mechanical and Electrical

The assembled elements of a device that raises, transports or compresses fluids by mechanical action.

Only includes pumps fixed in a particular location. Mobile pumps which are transported to be used at various locations are not included in this definition.

Pump assemblies are displayed in AIMS as a point at the centre of the structure.

Please note that this asset sub-type and its elements have been added to the DRL for test and demonstration purposes only.

20-01-2021

Elements

An Element Type is a component part of an Asset Type. Each Asset Type (except Asset Complex assets) will comprise of a prescribed set of Element Types.  Some Element Types are essential and must be present to define an asset of that Asset Type.  Other Element Types are optional, to be included when needed to define a particular Asset Type instance. An individual asset may have more than one instance of each Element Type.

This table lists the Element Types applicable to this Asset Type.

Element TypeDescriptionElement CodeEssentialUniclass 2015Updates
BellowsA pipe expansion joint, an inset section for a pipe to allow for expansion and misalignment.BELNo20-01-2021
Cathodic ProtectionA corrosion protection system applied to ferrous metal structures and pipeline.CTHNoPr_65_70_1320-01-2021
DampersDevices which reduce movement or vibration by dissipating energy.DMPNoPr_20_29_10_2120-01-2021
Draindown FountainA pipe fitting designed to allow water to be drained from a pipeline with minimal effect on the surroundings, which aerates water before it discharges into a river. It is essentially an inverted bell mouth connected to control valves.DDFNo20-01-2021
Electricity MeterA device installed on an asset with an electricity supply to record the amount of electricity used. This can automatically send readings to a host system for monitoring purposes.EMTNoSs_75_70_54_2520-01-2021
Electricity Sub MeterA smaller device installed on an asset with an electricity supply to record the amount of electricity used, this will not feed back readings to a host system but can be read manually to record the electrical usage of an asset that has multiple electrical elements or an asset complex.ESMNoSs_75_70_54_2520-01-2021
Filter or StrainerA specialist powered device to strain water which automatically cleans itself when blocked.FLSNoPr_65_57_95_9620-01-2021
GearboxPart of transmission used for regulating power from an engine.GBXNoPr_85_50_27_2820-01-2021
MotorA machine that uses electricity to produce movement, to make a machine work.MOTNoPr_75_51_2620-01-2021
Pipe JointA specialised mechanical joint or coupling used to connect two sections of pipe, e.g. Victaulic, Viking Johnson (VK).PJTNoPr_65_52_6220-01-2021
PipeworkA system of pipes used to convey fluids in or between assets.PWKNoPr_65_52_6320-01-2021
PumpA device that raises, transports or compresses fluids by mechanical action.PMPYesPr_65_53_2420-01-2021
Pump ValvesDevices which control the flow of liquid through a pump.PMVNoPr_65_54_30_1220-01-2021
SpringsAn elastic device, typically a metal coil/helix, that can be compressed or stretched but returns to its former shape when released. Used primarily to exert constant tension or absorb movement.SPRNoPr_20_29_10_2120-01-2021
Surge VesselA product used to absorb the impact from a sudden change in the flow of water.SGVNoPr_60_5020-01-2021
Vertical Extended SpindleThe vertical rotating axis of a machine such as a pump.VESNoPr_65_53_65_9420-01-2021
Request new Element

Attributes

An attribute is a particular piece of data that describes a property of an object. Each Asset Type is described by a different set of attributes, although there are some attributes that are common to many Asset Types.

The table below lists the attributes that are applicable to this Asset Type, along with the data profile requirements for each attribute and details of when and how each should be used and delivered.

AttributeFormat DetailsDeliveryPurposeMandatorygeoCOBie MappingUpdates
Asset Ref
Unique asset reference code in scheme context assigned by scheme designer eg MP0123
Text
Subtype code MP + sequence number
EA2Feature.Attribute.Name.AssetRef18-02-2021
Bounding Box
Geospatial orthogonal bounding box cube containing extent of asset.
json lineString [lower left point easting, northing, elevation, upper right point easting, northing, elevation] metres.
For future use; included for test purposes.
GeometryEA3Feature.Attribute.Name.BoundingBox29-01-2021
Control LineString
A spatial lineString that locates the asset and further classified by the associated LineStringType attribute confirming its relative location to the asset.
A lineString is a series of design or measured spatial triple points (easting, northing, elevation) each connected by a single non-crossing line, with single points at each end, that locate an asset. A lineString is expressed as a JSON array of type geoJSON lineString and is further classified by the associated LineStringType attribute confirming its relative location to the asset. Interim points should be spaced at a maximum of 2m for lines < 10m in length, or 10m otherwise. LineStrings may be open as in the case of linear asset types or closed (polygon) in the case of land or site assets. For linear assets, see the note in the description above about the maximum length.
The default CRS is a 3D CRS to EPSG 7405 with confirmed type, European reference frame and UK OS transformation e.g. 'lineString:7405:ETRS89:OSTN15:OSGM15'.
For future use; included for test purposes.
GeometryEA2Feature.Attribute.Name.ControlLineString29-01-2021
Downstream Asset Ref
The Asset Reference of the immediately adjacent downstream asset that forms part of the continuous flood defence.
For future use; included for test purposes.
Text
Max Length: 7
EA2Feature.Attribute.Name.DownstreamAssetRef29-01-2021
LineString Type
The type of the Control LineString.
For future use; included for test purposes.
Picklist
Axial Crest Invert
EA2Feature.Attribute.Name.LineStringType29-01-2021
Upstream Asset Ref
The Asset Reference of the immediately adjacent upstream asset that forms part of the continuous flood defence.
For future use; included for test purposes.
Text
Max Length: 7
EA2Feature.Attribute.Name.UpstreamAssetRef29-01-2021